All-Fuel Chimney Slide#1
All-Fuel Chimney Slide#2
Res Home Page Slide#3
Home Page Slide#4
transparent_image
Aluminum Liners

All-Fuel Temp/Guard® Chimney

Model - TG

Double-Wall Factory-Built Chimney Systems for use with listed wood, coal, oil, gas or propane-fired appliances in accordance with the Standards for Chimneys, Fireplaces, Vents and Solid-Fuel Burning Appliances, NFPA 211, BOCA National Mechanical Code, Standard Mechanical Code and the Uniform Mechanical Code.
spacer
TG Group

Temp/Guard®

Double Wall Insulated Chimney
Temp/Guard® All-fuel products, diameters 6"- 8" are tested and listed to UL 103HT for continuous operating temperatures up to 1000°F and 2100°F intermittent.  Temp/Guard features a twist-lock connection that eliminates the need for sheet metal screws and aids in proper joint alignment.  Temp/Guard utilizes a ceramic fiber blanket insulation that reduces “hot spots” and prevents insulation settling during transportation and installation, increasing product safety and reliability.  Our factory-built chimneys have the smallest clearance to combustibles of 1.5" in the industry, reducing the chimney system footprint that saves on cost and time.
 
Application
Factory-built double wall chimney for use with listed wood, coal, oil or gas-fired appliances.
Listings/Standards
NFPA 211
UL 103HT
Construction
Flue Material Specifications:
    6" - 8"/.015, 430 stainless steel
    
Casing Material Specifications:
    Galvanized/Stainless Steel
    6" - 8"/.018, galvanized; .015, 430 stainless steel
Diameters
6" -8"
Clearances
1-1/2" Minimum clearance to combustibles for 6"-8"
 
TG Product Grouping

Temp/Guard®

Double Wall Insulated Chimney
Temp/Guard® All-fuel products, diameters 10"-12" are tested and listed to UL 103HT for continuous operating temperatures up to 1000°F and 2100°F intermittent.  Temp/Guard features a twist-lock connection that eliminates the need for sheet metal screws and aids in proper joint alignment.  Temp/Guard utilizes a ceramic fiber blanket insulation that reduces “hot spots” and prevents insulation settling during transportation and installation, increasing product safety and reliability.
 
Application
Factory-built double–wall chimney for use with listed wood, coal, oil or gas-fired appliances.
Listings/Standards
NFPA 211
UL 103HT
Construction
Flue Material Specifications:
    10" - 12"/.015, 430 stainless steel
    
Casing Material Specifications:
    Galvanized/Stainless Steel
    10" - 12"/.018, galvanized; .015, 430 stainless steel
Diameters
10" - 12"
Clearances
2" Minimum clearance to combustibles for 10"-12"
 
TG Product Grouping

Temp/Guard®

Double Wall Insulated Chimney
Temp/Guard® All-fuel products, diameters 14"-18" are tested and listed to UL 103 for continuous operating temperatures up to 1000°F and 1700°F intermittent.  Temp/Guard features a precision laser welded flue with a male to female slip connection secured with sheet metal screws.  Temp/Guard utilizes a ceramic fiber blanket insulation that reduces “hot spots” and prevents insulation settling during transportation and installation, increasing product safety and reliability.
 
Application
xFactory-built double–wall chimney for use with listed wood, coal, oil or gas-fired appliances.
Listings/Standards
NFPA 211
UL 103
Construction
Flue Material Specifications:
    14" - 18"/.035 430 stainless steel
    
Casing Material Specifications:
    14" - 18"/.024, galvanized steel
Diameters
14" - 18"
Clearances
2" Minimum clearance to combustibles for 14"-18"
 
  × Type-B Gas Vent Adaptability Training